Hardware Installation
b. Tighten the wire-clamp screws to prevent the wires from coming loose.
PWR1 and PWR2 support power redundancy and reverse polarity protection.
• If both power inputs are connected, the ES8508 is powered from the highest connected voltage.
• The ES8508 can emit an alarm if PW1 or PW2 are no longer receiving power. See the
discussion on
2. Connect a ground wire between the chassis and earth ground using
12-24AWG wire to ensure that the ES8508 is not damaged by noise
or electrical shock.
a. Loosen the earth ground screw on the bottom of the ES8508.
b. Insert the ground wire.
c.
Tighten the ground screw after the earth ground wire is
connected.

Connect the Digital Input and Relay Outputs

The ES8508 provides one digital input and one digital output (dry relay output) on the terminal block
connectors on the bottom of the unit. The fault conditions can be configured in the web user interface or
Command Line Interface (CLI) and include:
Power Failure
Port Link
Ring
Ping
Ping Reset
Dry output
DI
You can configure events using one of the ES8508 user interfaces
Line Interface
(Global Configuration Mode
The Digital Input pin can be pulled high or low so that the connected equipment can actively drive these pins.
The web user interface allows you to read and set the value to the connected device. The power input voltage
of logic low is 0 to 10VDC and logic high is 11 to 30VDC. Do not apply a higher voltage than the specification;
it may cause internal circuit damage or a cause an incorrect DI action.
Earth
Digital Input
10 - Connect the Digital Input and Relay Outputs
Page 116
to configure an alarm.
on Page 141).
DO
DI1
- +
- +
(Fault Relay
on Page 116) or the Command
Sensor
1 = High Output: 11-30VDC
0 = Low Output: 0-10VDC
Sensor
RocketLinx ES8508 Series User Guide: 2000575 Rev. A