Data Processor - Konica Minolta CR-400 Instruction Manual

Chroma meter
Hide thumbs Also See for CR-400:
Table of Contents

Advertisement

Specifications
<Data Processor>
Name
Model
Display range
Measurement time
Minimum measurement interval
Battery performance
Illuminants
Display
Tolerance judgment
Color system / Color space /Colo-
rimetric data
Languages
Storable data sets
Color difference target colors
Calibration channels
Page function
Display
Printer
Statistical function
Automatic measurement
Interface
Power source
Size
Weight
Operating temperature/
humidity range (*1)
Storage temperature/humidity range
*1 Operating temperature/humidity range of products for North America: 5 to 40ºC, less than 80% relative humidity at 31ºC with no condensation
152

Data Processor

DP-400
*
Y: 0.01 to 160.00% (reflectance)
*
1 sec.
3 sec.
Approx. 800 measurements
test conditions)
C, D65
Chroma values, color difference values, color difference graphs,
*
PASS/WARN/FAIL display
Color difference tolerance (box tolerance and elliptical tolerance)
*
Only for the display function
XYZ, Y x y, L*a*b*, Hunter Lab, L*:C*h, Munsell (only illuminant C), CMC
(l:c), CIE1994, Lab99, LCh99, CIE2000, CIE WI-Tw (only illuminant D65),
WI ASTM E313 (only illuminant C), YI ASTM D1925 (only illuminant C),
YI ASTM E313 (only illuminant C), User index (up to six registered in the
Measuring Head can be used)
Operating keys: English
LCD : English (default), German, French, Italian, Spanish, Japanese
Max. 2000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are
*
possible
Only for the operating function (100 pieces of data when the measuring head
is connected; input of measurement values or numeric)
*
(independent of page function)
Only for the operating function (20 channels when the measuring head is con-
nected) (ch00: white calibration; ch01 to ch19: user calibration)
100 pages
Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display)
Contrast adjustment
384 dot line thermal printer (can also print graphs)
Automatically prints out all measurement results (can be set not to)
*
Maximum, minimum, average, and standard deviation
Date and time display: year, month, day, hour, minute
Timer: 3sec. to 99 min. (Some measurement modes require more than 3 sec.)
RS-232C compliant
USB2.0 (When using the USB-Serial Converter Cable CR-A105, 2 m)
Baud rate (bps): 19200 fixed (when connected to PC)
When measuring head is connected baud rate is automatically set to that of the
measurement head
AA alkaline or NiMH batteries x 4
AC adapter (AC-A305) AC100-240V
100(W) x 73(H) x 259(D)mm
Approx. 600g (not including
0 to 40°C, relative humidity 85% or less
-20 to 40°C, relative humidity 85% or less
(When using batteries under Konica Minolta's
24-38VA 0.24-0.16A 50/60Hz
batteries, cables and
paper)
(at 35ºC with no condensation)
(at 35ºC with no condensation)