3. Commissioning
1st position
2nd position 3rd position
4
E (= error)
1st position
2nd position 3rd position
1
E (= error)
u (= Warning)
1
4
Festo CPX-CM-HPP-EN 2017-06b English
Error during initialisation
In the event of errors, the initialisation will stop at the faulty
axis. The error number is displayed continuously, e.g.
Significance
1
Axis 4 shows Error 1
The initialisation will not continue until the error has
been eliminated. For an overview of error numbers,
see Chapter 4.2.3.
Error after initialisation
Errors that occur during operation are shown with an
alternating display. First, the error type is shown (error or
warning), followed by the error number. The duration of the
display is approximately 0.5 s each. The example below
shows the display for Error 44 on Axis 1:
Significance
Axis 1 shows error type "Error" or "Warning"
4
Axis 1 shows Error 44
For an overview of error numbers, see Chapter 4.2.3.