4. Diagnostics and error treatment
1st position
2nd position
Axis no.
Mode/
Error no.
in
Initialization
S
Set selection
d
Direct mode
E
Error
12
u
Warning
28
Tab. 4/3:
Information on the three-digit 7-segment display
4-12
3rd position
Significance
Status/
Error no.
Display initialisation
Connection set-up and initialisation of the axes
consecutively. The initialisation for the next axis
will not start until the initialisation for the current
axis has been completed successfully.
0
Axis is switched on (Axis is READY)
1
Controller enable (Axis is ENABLED)
2
Axis is referenced (Axis is REFERENCED)
0
Axis is switched on (Axis is READY)
1
Controller enable (Axis is ENABLED)
2
Axis is referenced (Axis is REFERENCED)
Error No.: 12
First, the display shows "E" and then "12".
Warning: 28
First, the display shows "u" and then "28".