Configuration Item Table - IDEC WB2F User Manual

2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
4. 6

Configuration Item Table

The settings and setting values that define the manner in which the WB2F operates are as follows.
You can define the customized operation of the WB2F for your environment by changing the setting values.
When setting values are changed, the setting values must be saved with the "save setting values" con-
z
trol command.
If the power is turned off, the unit is reset, or the operation mode is changed without executing "save
z
setting values", the setting values are restored to the same values as before they are changed.
Do not access or change any settings that are not listed here.
z
Do not access or change any settings in reserved areas.
z
Do not access or change any settings during a reading operation.
z
When configuring settings that specify ASCII code for the setting value, be aware of the following points.
NUL (00H) cannot be used as a setting value.
z
The characters up to the first NUL (00H) are considered the data and any data after that is not valid.
z
Setting value (hex) of bold face is default value (Setting at the time of factory shipments).
Item
Sub item
Reserved
Communication
speed
RS-232 settings
Data length
Parity
Stop bits
Flow control
Reserved
Reserved
OUT0
External Output
Reading Linked
settings
Control
Reserved
3 Operational Check
Address
Size
Default
(hex)
(dec)
(hex)
0000-01FF
256
-
0100
1
03
0101
1
01
0102
1
01
0103
1
00
0104
1
00
0105-010F
11
-
0110-011F
16
-
0120
1
01
0121
1
-
4-54
Function
Setting value
(hex)
-
00 : 1,200bps
01 : 2,400bps
02 : 4,800bps
03 : 9,600bps
04 : 19,200bps
05 : 38,400bps
06 : 57,600bps
After saved, the settings are
07 : 115,200bps
reflected when the power is
0a :
600bps
turned on, the WB2F is reset,
00 : 7bits
or the operation mode is
01 : 8bits
changed.
00 : NONE
01 : EVEN
02 : ODD
00 : 1bit
01 : 2bits
00 : None
01 : CTS/RTS
-
-
00 : Disabled
Enable to link to the reading
01 : OK Output Enabled
operation.
-