IDEC WB2F User Manual page 125

2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
Methods to fix the length of read symbols
Fixed Length A and Fixed Length B setting configurations are only available for applicable symbols
There are three methods to fix the length.
Fixed length method
Specify range
Fixed length A < fixed length B Fixed length A to fixed length B
Specify fixed length
Fixed length A ≥ fixed length B Fixed length A, fixed length B
Not specified
Fixed length A=00H
Specified Range
You can specify a range for the length by setting the minimum symbol length to read for fixed length A and setting the 
maximum for fixed length B (fixed length A < fixed length B). However, do not set fixed length A as "00H". A range cannot
be specified in that way.
e.g. When fixed length A is set to "02H" and fixed length B is set to "08H"
If Fixed Length A< Fixed Length B, only symbols with a range of 2 to 8 characters can be read
Specify fixed length
If the setting value for fixed length A is larger than that of fixed length B (fixed length A > fixed length B), two types of
fixed lengths can be set. If fixed length B is "00H", only the length set by fixed length A can be read.
If fixed length A and fixed length B are set to the same value (fixed length A=fixed length B), only the fixed length that has
been set can be read.
e.g. When fixed length A is set to "08H" and fixed length B is set to "02H"
If Fixed Length A> Fixed Length B, only symbols with a range of 2 to 8 will be read.
e.g. When fixed length A is set to "05H" and fixed length B is set to "05H"
If Fixed Length A= Fixed Legth B, only symbols with 5 characters can be read.
Fixed length not specified
If Fixed Length A is set to 00H, no fixed range is set for the value of fixed length. Any symbol with a range of minimum to
maximum (depending on the symbol) number of characters can be read.
e.g. When fixed length A is set to "00H"
If Fixed Length A = 00H, any symbol with a range of minimum to maximum (varies depending on the symbol) num-
ber of characters can be read
Confirm each symbols decoding settings for the readable Number of Characters (minimum value, maximum
value)
3 Operational Check
Configuration method
4-89
Function
Readable length
Minimum value to maximum value (varies by symbol)
5. Appendix