IDEC WB2F User Manual page 78

2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
z Detailed procedure using the READ/ENTER and SELECT buttons
1
When the unit's power supply is on, push the READ/ENTER button
for 5 seconds.
The Status LEDs (green/orange/red) will flash and the unit will
switch to the waiting state for measurement item to be selected in
setup support mode.
If 5 seconds elapse with no operation, the unit returns to
the same operation mode as before you switch.
2
Push the SELECT button.
The Status LED (green) will flash and the unit will switch
to the waiting state for Reading Success Rate measure-
ment to be executed.
To select the Decoding Processing Time measurement,
push the SELECT button.
The Status LED (orange) will flash prior to the decode
processing measurement time switching to standby.
To select the Symbol Position measurement, push the
SELECT button.
The status LED (red) will flash prior to the Symbol Posi-
tion measurement function switching to standby.
3 Operational Check
Wait for Reading Success Rate
measurement to be executed.
Wait for Decoding Processing Time
measurement function to be executed.
Wait for Symbol Positionmeasurement
4-42
Function
5. Appendix
Setup support mode
5 s
Status LEDs
(R)
(O)
Wait for measurement
item to be selected.
Status LEDs
(R)
(O)
Status LEDs
(R)
(O)
Status LEDs
(R)
(O)
function to be executed.