1. Overview
2. Installation & wiring
Maximum flshing time of emitter LED is affected by frame arte and Flashing mode.
Each light's maximum lighting time is as follows.
Resolution
QuadVGA
720P
WVGA
If read time out elapses, all processes will cease
z
Make sure you choose a decode timeout value that is less than the Reading timeout value
z
Filter time can be set at any value between 1 to 100ms
z
It is configurable of range 100 to 25,500 ms and Infinite.
z
Decode Timeout can be set at either Infinite or any value between 100 to 25,500ms
z
Exposure time can be set at any value between 0.09 to 10.00ms
z
Maximum image processing time is 27.80ms
z
5. 5. 2

External Output Timing Chart

z OK/NG Output
OK Output turns ON when Reading Success or Verification Success occurs
NG Output turns ON when Read Failure or Verification Failure occurs
Operating logic of output can be chosen from "positive logic" and "negative logic".
The timing chart when set to [positive logic] is as follows:
Reading Request
Image + Decode
ON
External Output
(OK/NG)
OFF
Output enable time can be set as infinite, or any value between 10 to 2,550 ms.
z
While OK Output or NG Output was on, when a reading request became on the outside output is turned off
z
compulsorily.
3 Operational Check
Image quality
Frame rate
High
Low
High
Low
High
Low
Output Duration
5-11
4 Function
Normal usage
36fps
60fps
40fps
5ms
60fps
60fps
60fps
When OK/NG output had a reading request in on.
Output is turned off compulsorily.
Appendix
Timing Chart
Lighting ON Mode
Boost
1.4ms
0.8ms
1.0ms
0.8ms
0.8ms
0.8ms