Configuration item table

The settings and setting values that define the manner in which the WB1F operates are as follows.
You can define the customized operation of the WB1F for your environment by changing the setting values.
In addition, you can change to the setting value by reading the barcode which is described in menu sheet (WB1F-MENU-
SHEET-E, B-1782).
When setting values are changed, the setting values must be saved with the "save setting values" control
z
command.
If the power is turned off, the unit is reset, or the operation mode is changed without executing "save setting
values", the setting values are restored to the same values as before they are changed.
Do not access or change any settings that are not listed here.
z
Do not access or change any settings in reserved areas.
z
When configuring settings that specify ASCII code for the setting value, please be aware of the following
z
points.
- NUL (00H) cannot be used as a setting value.
- The characters up to the first NUL (00H) are considered the data and any data after that is not valid.
Setting value (hex) of bold face is default value (Setting at the time of factory shipments).
Note the following points when configuring items related to the decoder.
z
Setting all symbols that will not be used as Reading prohibited is recommended.
If multiple symbols of the following are set to Reading allowed, unexpected read results may be output de-
pending on the symbol specifications.
-- Code39, CIP39, Italian Pharm
Use "All symbology Reading allowed/prohibited" to rewrite the read allowed/prohibited setting values in the
decoder settings for each symbology at once.
Make sure the final read allowed/prohibited status is configured as intended for each symbology.
Item
Sub item
Reserved
Communication
speed
RS-232 settings
Data length
Parity
Stop bits
Flow control
Reserved
Function
Address
Size
Default
(hex)
(dec)
(hex)
0000-01FF
256
-
0100
1
03
0101
1
01
0102
1
01
0103
1
00
0104
1
00
0105-011F
27
-
4. Support tool
Setting value
(hex)
-
00:
1,200 bps
01:
2,400 bps
02:
4,800 bps
03: 9,600 bps
04: 19,200 bps
05: 38,400 bps
06: 57,600 bps
07: 115,200 bps
After saved (save), the settings
0a:
600 bps
are reflected when the power
00: 7 bits
is turned on, the unit is reset, or
01: 8 bits
the operation mode is changed.
00: None
01: Even
02: Odd
00: 1 bit
01: 2 bits
00: None
01: CTS/RTS
-
5. Appendix
Configuration item table