1. Overview
2. Installation & wiring
4. 2. 7

Communication command

Communication command transmits/receives various types of data from the host device connected via the WB2F's com-
munication interface. The applications required to transmit/receive data are collectively called [communication com-
mand]
For details of various settings of the communication command function, refer to
Table]
on
page 4-54
Communication Commands are composed of both Control Commands and Setup Commands
Control Command
Command to directly start up the WB2F. It can also execute other actions such as Symbol Reading, the Status LED ON/OFF
etc.
Setup Command
This command can be used to change or acquire the WB2F's parameter settings such as RS-232 communications, the Sta-
tus LED patterns, times etc.
Communication Data Format: Regarding Prefix and Suffix
Excluding prefix and suffix, communication data formats of communication commands are text (ASCII format)
z
Based on useage environment, prefix and suffix can be changed
z
This section is written assuming that the scanner has maintained its factory default settings
z
Notes on Communication
Enter [prefix + suffix] if you suspect any of the following: the scanner is unused despite the power being on
z
for a long period of time, the scanner appears to be receiving noise, or the scanner may be storing unnces-
sary data in its reception buffer. This will clear the reception buffer.
The transmission and receive buffers have 16kB of storage. If data that exceeds 16kB is stored, data transmis-
z
sion and reception will not be correctly performed. If you plan on enabling the RS-232 interface's hardware
flow control, keep the storage limitation in mind.