1. Overview
Installation & wiring
z Wiring for External Input
External Input is a trigger input used to turn Read Request ON/OFF.
External Input will operate given the following voltage input (VIL:0-5V, VIH: 15-28.8V).
Refer to the following example prior to wiring the WB2F.
Communication Unit
Input to
the WB2F
Caution
Caution
Miswiring may cause damage to internal circuitry.
Use an AWG16 to 24 Cable for wiring.
z Wiring for External Output
External Output is used to determine read success/read failure during read operations.
Refer to the following example prior to wiring the WB2F.
Communication Unit
R
Output
from WB2F
(NPN Open Collector)
Caution
Caution
Miswiring may cause damage to internal circuitry.
If the Load and the WB2F are connected to separate power supplies, make sure that you turn the WB2F's
z
power on first.
Use an AWG16 to 24 Cable for wiring.
z
3. Operational Check
VCC
R
R
0V
VCC
R
2-11
4. Function
IN_0,1
R
24V DC
R
IN_COM
(28.8V DC max.)
OUT_0-3
Load
OUT_COM
5. Appendix
Wiring
24V DC
(30V DC max.)