IDEC WB2F User Manual page 47

2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
z Start Reading and Stop Reading conditions for each Reading Request
Symbol Reading and Reading Request
Symbol Reading Reading Timeout
100ms to 25,500ms
(Edge Activation)
Single Read
Infinite
(level activate)
100ms to 25,500ms
(Edge Activation)
Multi-Read
Sequential
Output
Infinite
(level activate)
100ms to 25,500ms
(Edge Activation)
Multi-Read
Batch Output
Infinite
(level activate)
*1 Symbol Reading executed via the READ/ENTER button forcibly executes fixed operation of single read edge activation
(Reading Timeout: 5s)
If you initiate symbol reading using a Control Command, after the symbol reading is stopped, Reading Request
will automatically turn OFF
3 Operational Check
Reading Request
Start Reading Conditions
READ/ENTER button
Push the READ/ENTER button
External Input
External Input OFF → ON
Control command
Start Reading Command Input
READ/ENTER button
External Input ON
External Input
(Continues to read only while
Trigger is ON)
Control command
Read Start Command Input
READ/ENTER button
External Input
External Output OFF → ON
Control command
Start Reading Command Input
READ/ENTER button
External Input ON
External Input
(Continues to read only while
Trigger is ON)
Control command
Start Reading Command Input
READ/ENTER button
External Input
External Output OFF → ON
Control command
Start Reading Command Input
READ/ENTER button
External Input ON
External Input
(Continues to read only while
Trigger is ON)
Control command
Start Reading Command Input Input Stop Reading Command
4-11
Function
5. Appendix
Operation
Stop Reading Conditions
Reading Success
z
Reading Timeout (5s) Elapsed
z
Reading Success
z
Reading Timeout Elapsed
z
Reading Success
z
Reading Timeout Elapsed
z
Input Stop Reading Command
z
*1
Reading Success
z
External Input OFF
z
Reading Success
z
Input Stop Reading Command
z
*1
Reading Timeout Elapsed
z
Reading Timeout Elapsed
z
Input Stop Reading Command
z
*1
External Input OFF
z
Input Stop Reading Command
z
*1
Reading Timeout Elapsed
z
Reading Timeoute Elapsed
z
Input Stop Reading Command
z
*1
External Input OFF
Slave Mode

Advertisement

Table of Contents
loading

Table of Contents