1. Overview
2. Installation & wiring
No.
Name
Prefix
Start symbol position
33
^
measurement
Start symbol position
measurement (Read-
34
^
ing parameter table
specification)
Switch to Setup sup-
35
port mode (standard
^
adjusting)
Swithc to Setup sup-
36
port mode (specialized
^
adjusting)
Status transition of
37
Setup support mode
^
(custom adjusting)
38 Switch to slave mode ^
Switch to maintenance
39
^
mode
Reset (after 10 sec-
40
^
onds)
41 Reset (after 5 seconds) ^
42 Reset (after 1 second) ^
43 Load setting values
^
44 Save setting values
^
45 Initialize setting values ^
46 Get version
^
Get communication
47
settings
^
(Current value)
3 Operational Check
Control command
Mnemonic
Suffix
CR
LF
sup2
CR
LF
sup2 xx
CR
LF
tune0
CR
LF
tune1
CR
LF
tune2
CR
LF
slave
CR
LF
mainte
CR
LF
reset10
CR
LF
reset5
CR
LF
reset
CR
LF
load
CR
LF
save
CR
LF
iNiTiAl
CR
LF
ver
CR
LF
comgetc
5-15
4 Function
Description
It is changed to position assist mode and ssymbol posi-
tion measurement is started.
It is changed to position assist mode and symbol posi-
tion measurement in a reading parameter table is start-
ed. xx can choose 00 to 07.
Refer to
F [5. 7 Control Commands (Details)]
5-17.
Specialized adjusting is performed for symbol printed on
paper which the reading as easy.
Specialized adjusting is performed for symbol(DPM, etc)
printed which the reading as difficult.
This function is adjusting value of the auto configuration
after confured value of the auto configuration.
Switches to slave mode.
Switches to maintenance mode.
Executes a reset after 10 seconds.
Executes a reset after 5 seconds.
Executes a reset after 1 second.
Loads the setting values from the currently selected set-
ting value region (non-volatile memory).
Saves the setting values to the currently selected setting
value region (non-volatile memory).
While saving, the Status LED (orange) will blink.
Saving will complete within 5s.
Resets all setting values to the factory defaults.
During initialization, the Status LED (orange) will blink.
Time to complete initialization is within 30s.
Gets the version of the firmware.
Example: Response when getting the version
^WB2F-100S1B/A-001.000.00/B-001.000.00
CR
LF
For details, refer to
F [5. 7 Control Commands (Details)]
on
page
5-17.
Gets the RS-232 interface communication settings. (Cur-
rentvalue)
Example: Response when getting the current values of
the communication settings
^07,01,01,00,00/00,00,00,00/5e,00,00,00/0d
,0a,00,00 CR
LF
(^baud rate, data length, parity, stop bits, flow con-
trol/reserved, add check digit, uppercase response,
reserved/4 prefixes/4 suffixes
For details, refer to
F [5. 7 Control Commands (Details)]
on
page
5-17.
Appendix
List of Control Commands
on
page
CR
LF
)