IDEC WB2F User Manual page 144

2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
No.
Name
Prefix
Status LED (Orange)
19
^
OFF
Status LED (Orange)
20
^
ON
21 Status LED (Green) OFF ^
22 Status LED (Green) ON ^
Initialize temporary
23
^
image memory
Initialize non-volatile
24
^
image memory
Retrieve free tempo-
25
rary image memory
^
file count
Retrieve non-volatile
26
image memory file
^
count
Acquire temporary
27
Image memory file
^
data
Acquire non-volatile
28
image memory file
^
data
Reading success rate
29
^
measurement starting
Reading success rate
measurement starting
30
^
(Reading parameter
table selected)
Start Decoding Pro-
31
cessing Time Measure-
^
ment
Start Decoding Pro-
cessing Time measure-
32
^
ment (read parameter
table specification)
3 Operational Check
Control command
Mnemonic
Suffix
CR
LF
ledb0
CR
LF
ledb1
CR
LF
ledc0
CR
LF
ledc1
CR
LF
fs_fmta
CR
LF
fs_fmtb
CR
LF
fs_blka
CR
LF
fs_blkb
CR
LF
fs_geta yyyy
CR
LF
fs_getb yyyy
CR
LF
sup0
CR
LF
sup0 xx
CR
LF
sup1
CR
LF
sup1 xx
5-14
4 Function
Description
Sets the Status LED (orange) to the OFF State
Sets the Status LED (Orange) to the ON State
Sets the Status LED (Green) to the OFF State
Sets the Status LED (Green) to the ON State
Initializes temporary image memory.
During initialization, the Status LED (orange) will blink.
Time to complete initialization is within 5s.
Initializes non-volatile image memory.
During initialization, the Status LED (orange) will blink.
Time to complete initialization is within 30s
To get remaining of number of to acquire temporary im-
age in memory.
It is not possible to store temporary image in memory
when a reply of the number of remaining files will be
0000.
Execute to initialize temporary image memory when you
would like to get new temporary image.
Refer to
F [5. 7 Control Commands (Details)]
5-17.
To get remaining of number of to acquire non-volatile
image in memory.
It is not possible to store non-volatile image in memory
when a reply of the number of remaining files will be
0000.
Execute to initialize non-volatile image memory when
you would like to get new non-volatile image.
Refer to
F [5. 7 Control Commands (Details)]
5-17.
Data of a specified number file in the temporary picture
memory is acquired. yyyy can choose 0000 to 0015.
Refer to
F [5. 7 Control Commands (Details)]
5-17.
Data of a specified number file in the non-volatile picture
memory is acquired. yyyy can choose 0000 to 0015.
Please refer to
F [5. 7 Control Commands (Details)]
page
5-17.
Switches to setup support mode and starts the setup
support function reading success rate measurement.
It is changed to position assist mode and reading suc-
cess rate measurement in a reading parameter table is
started. xx can choose 00 to 07.
Refer to
F [5. 7 Control Commands (Details)]
5-17.
It is changed to position assist mode and Decoding Pro-
cessing Time measurement is started.
It is changed to position assist mode and Decoding Pro-
cessing Time measurement in a reading parameter table
is started. xx can choose 00-07.
Refer to
F [5. 7 Control Commands (Details)]
5-17.
Appendix
List of Control Commands
on
page
on
page
on
page
on
on
page
on
page

Advertisement

Table of Contents
loading

Table of Contents