List Of Control Commands - IDEC WB2F User Manual

2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
5. 6

List of Control Commands

No.
Name
1 Start Reading
Start Reading (Read
2
Parameter Table Speci-
fication)
Start Designated Area
3
Reading
Start Designated Area
4
Reading (read parame-
ter table specification)
5 Stop Reading
6 Snap Shot
Snap Shot (Reading
7
parameter table speci-
fication)
Image Memory Bitmap
8
Image Acquisition
Image Memory JPEG
9
Image Acquisition
10 Verification Start
11 External Output 0 OFF ^
12 External Output 0 ON ^
13 External Output 1 OFF ^
14 External Output 1 ON ^
15 External Output 2 OFF ^
16 External Output 2 ON ^
17 Status LED (Red) OFF
18 Status LED (Red) ON
3 Operational Check
Control command
Prefix
Mnemonic
^
get
^
get xx
^
rget Sx Sy Ex Ey
^
rget xx Sx Sy Ex Ey
^
stop
^
sshot
^
sshot xx
^
iget
^
icget
^
cmp**
outputa0
outputa1
outputb0
outputb1
outputc0
outputc1
^
leda0
^
leda1
5-13
4 Function
Suffix
CR
LF
Start symbol read
The Symbol Reading using the reading parameter table
is started. xx can choose 00-07.
CR
LF
Refer to
F [5. 7 Control Commands (Details)]
5-17.
The designated area reading is started. Sx,Sy,Ex,Ey inputs
coordinate data.
CR
LF
Refer to
F [5. 7 Control Commands (Details)]
5-17.
The designated area reading using the reading parame-
ter table is started. Sx,Sy,Ex,Ey inputs coordinate data.
CR
LF
Refer to
F [5. 7 Control Commands (Details)]
5-17.
CR
LF
Stops symbol reading
Only captured imaging is performed.
CR
LF
The captured imaging is stored in the imaging memory.
Only captured imaging in a reading parameter table is
performed. xx can choose 00-07.
CR
LF
The captured imaging is stored in the imaging memory.
Refer to
F [5. 7 Control Commands (Details)]
5-17.
The image data stored in the Bitmap imaging memory is
acquired.
CR
LF
Refer to
F [5. 7 Control Commands (Details)]
5-17.
The image data stored in the JPEG imaging memory is
acquired.
CR
LF
Refer to
F [5. 7 Control Commands (Details)]
5-17.
Symbol Reading undergo verification.
The Verification results are output.
Sequentially input master data can be added to the out-
CR
LF
put data.
For further details, refer to
(Details)]
on
page
5-17.
CR
LF
Sets External Output 0 to the OFF State
CR
LF
Sets External Output 0 to the ON State
CR
LF
Sets External Output 1 to the OFF State
CR
LF
Sets External Output 1 to the ON State
CR
LF
Sets External Output 2 to the OFF State
CR
LF
Sets External Output 2 to the ON State
CR
LF
Sets the Status LED (Red) to the OFF State
CR
LF
Sets the Status LED (Red) to the ON State
Appendix
List of Control Commands
Description
on
page
on
page
on
page
on
page
on
page
on
page