IDEC WB2F User Manual page 91

2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
Item
Sub item
OUT0 polarity
OUT0 duration
OUT1 Reading
Linked Control
Reserved
OUT1 Polarity
External Output
settings
OUT1 duration
OUT2 Reading
Linked Control
Reserved
OUT2 polarity
OUT2 duration
OUT3 Reading
Linked Control
Reserved
3 Operational Check
Address
Size
Default
(hex)
(dec)
(hex)
0122
1
01
0123
1
0A
0124
1
02
0125
1
-
0126
1
01
0127
1
0A
0128
1
03
0129
1
-
012A
1
01
012B
1
00
012C
1
04
012D
1
-
4-55
Function
Setting value
(hex)
Positive Logic :
As OUT0 is output, the transister
(open collector output) will turn
OFF and become High state.
Negative Logic :
00 : Positive Logic
As OUT0 is output, the transis-
01 : Negative logic
ter (open collector ouput) will
turn ON and become Low state.
Setting values that are altered
will immediately be reflected in
output, even if during a reading
operation.
00 :
Infinity
01 - FF : Setting value by
10ms step
(10 ms to 2,550 ms)
00 : Disabled
Enable to link to the reading
02 : NG Output Enabled
operation.
-
Positive Logic :
As OUT1 is output, the transister
(open collector output) will turn
OFF and become High state.
Negative Logic :
00 : Positive Logic
As OUT1 is output, the transis-
01 : Negative logic
ter (open collector ouput) will
turn ON and become Low state.
Setting values that are altered
will immediately be reflected in
output, even if during a reading
operation.
00 :
Infinity
01 - FF : Setting value by
10ms step
(10 ms to 2,550 ms)
00 : Disabled
Enable to link to the reading
03 : BUSY Output En-
operation.
abled
-
Positive Logic :
As OUT2 is output, the transister
(open collector output) will turn
OFF and become High state.
Negative Logic :
00 : Positive Logic
As OUT2 is output, the transis-
01 : Negative logic
ter (open collector ouput) will
turn ON and become Low state.
Setting values that are altered
will immediately be reflected in
output, even if during a reading
operation.
00 :
Infinity
01 - FF : Setting value by
10ms step
(10 ms to 2,550 ms)
00 : Disabled
Enable to link to the reading
04 : FLASH Synchronous
operation.
output Enabled
-
5. Appendix
Configuration Item Table
Remarks

Advertisement

Table of Contents
loading

Table of Contents