IDEC WB2F User Manual page 94

2d code scanner
Hide thumbs Also See for WB2F:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
Item
Sub item
Symbol Reading
Reading Timeout
Preventing Double
Read Time
Reserved
Reading start
when power on
Reserved
Reserved
Symbol Reading
Decode Timeout
Reserved
Number of symbols
read
Output mode
Reading Result
Output Port
Reserved
3 Operational Check
Address
Size
Default
(hex)
(dec)
(hex)
0200
1
00
0201
1
14
0202
1
14
0203
1
-
0204
1
00
0205
1
-
0206
1
-
0207
1
05
0208-020D
6
-
020E
1
01
020F
1
00
0210
1
00
0211-021F
15
-
4-58
Function
Setting value
(hex)
00 : Single read
01 : Multi-Read sequential
output
02 : Multi-Read batch
output
Set the maximum time to
continue the reading opera-
tion from the occurrence of a
00 :
Infinity
reading request.
01 - FF : Setting value by
Set the setting value to infinity
100ms step
in the usage that the reading
(100 ms to 25,500 ms)
operation synchronizes with
the external input or the start/
stop symbol reading command.
00 :
None
Sets the time that the same
01 - FF : Setting value by
symbol will not be read when
100ms step
performing the Multi-Read.
(100 ms to 25,500 ms)
-
If new settings are enabled,
operations will commence in
00 : Disabled
accordance to the new settings
01 : Enabled
as soon as the WB2F is pow-
ered on or is switched to slave
mode.
-
-
00 :
None
01 - FF : Setting value by
100ms step
(100 ms to 25,500 ms)
-
01 - 20 : Number of symbols
Configures the Read Request
to be read per image
Symbol Number.
00 : Will output results even if
00 : Output
01 : Will not output results if
01 : Do not output
To configure the communica-
tion port to send the reading
data when to request by op-
erational button and external
00 :RS-232
input.
01 :USB
The configured communication
port is not affected by request
from RS-232 and Maintanace
Port.
-
5. Appendix
Configuration Item Table
Remarks
Read Result is less than the
number of Read symbols.
As soon as Read Request is
turned OFF, all results will
be output.
Read Result is less than the
number of read symbols.
As soon as Read Request is
turned OFF, the Character
String at the time of Read
Failure will be output.

Advertisement

Table of Contents
loading

Table of Contents