1. Overview
2. Installation & wiring
z Control Code Replacement
If control code (00H-1FH, 7FH) is included in Reading Result Data, characters will be replaced by designated characters (re-
placement characters) prior to output.
e.g. Setting up a replacement character with the following parameters.
Character Code
Replacement Character
The command code replacement occurs as follows.
41H
Character Code
Reading Result Data
41H
Character Code
Replacement
(Output Data)
You cannot use NUL (00H) as a replacement character.
z
If Data extraction and integration are enabled, command code replacement will be executed after the ex-
z
traction and integration are completed.
Control Code Replacement is executed only if the read was successful.
z
3 Operational Check
40H
@
Control Code
42H
43H
00H 45H
46H
A
B
C
E
NUL
Replacement
42H
43H
40H
45H
46H
A
B
C
@
E
Replacement
Character
Function
Control Code
47H
7FH 49H
4AH
4BH
F
G
I
J
DEL
Replacement
47H
40H
49H
4AH
4BH
F
G
@
I
J
Replacement
Character
4-21
5. Appendix
Slave Mode
Control Code
Control Code
08H 4DH
4EH
0AH
50H
K
M
N
BS
LF
Replacement
Replacement
40H
4DH
4EH
40H
50H
K
@
M
N
@
Replacement
Replacement
Character
Character
P