Control Commands List - IDEC WB1F Series User Manual

Fix linear ccd scanner
Hide thumbs Also See for WB1F Series:
Table of Contents

Advertisement

1. Overview
2. Installation & wiring
5. 5

Control commands list

No.
Name
1 Start barcode reading ^
2 Stop barcode reading ^
3 Start matching
4 OK output off
5 OK output on
6 NG output off
7 NG output on
PWM output off
8
(When successful set-
tings)
PWM output on
9
(When successful set-
tings)
PWM output off
10
(When failure settings)
PWM output on
11
(When failure settings)
12 Indicator LED (red) off ^
13 Indicator LED (red) on ^
Indicator LED (orange)
14
off
Indicator LED (orange)
15
on
Indicator LED (green)
16
off
Indicator LED (green)
17
on
Switch to setup sup-
18
port mode
(Reading rate)
Switch to setup sup-
19
port mode
(Reading count)
20 Switch to slave mode ^
Switch to maintenance
21
mode
3. Functions
Control command
Prefix
Mnemonic
get
stop
^
cmp[reference data]
^
ok0
^
ok1
^
ng0
^
ng1
^
pwma0
^
pwma1
^
pwmb0
^
pwmb1
leda0
leda1
^
ledb0
^
ledb1
^
ledc0
^
ledc1
^
sup0
^
sup1
slave
^
mainte
4. Support tool
Suffix
CR
LF
Starts barcode reading.
CR
LF
Stops barcode reading.
Starts barcode reading and performs matching.
The matching result is output.
CR
LF
Reference data to sequentially input can be added.
Example: ^cmp12345
CR
LF
Stops the OK output.
Starts the OK output. (Polarity and duration follow the set-
CR
LF
ting values.)
CR
LF
Stops the NG output.
Starts the NG output. (Polarity and duration follow the set-
CR
LF
ting values.)
CR
LF
Stops the PWM output.
Starts the PWM output. (Frequency, duration, and duty fol-
CR
LF
low the setting values.)
CR
LF
Stops the PWM output.
Starts the PWM output. (Frequency, duration, and duty fol-
CR
LF
low the setting values.)
CR
LF
Sets the indicator LED (red) to the off state.
Sets the indicator LED (red) to the on state. (Display pattern
CR
LF
and illumination time follow the setting values.)
CR
LF
Sets the indicator LED (orange) to the off state.
Sets the indicator LED (orange) to the on state. (Display
CR
LF
pattern and illumination time follow the setting values.)
CR
LF
Sets the indicator LED (green) to the off state.
Sets the indicator LED (green) to the on state. (Display pat-
CR
LF
tern and illumination time follow the setting values.)
Switches to setup support mode and starts the setup sup-
CR
LF
port function reading rate measurement.
Switches to setup support mode and starts the measure-
CR
LF
ment of the reading number of times with setup support
function.
CR
LF
Switches to slave mode.
CR
LF
Switches to maintenance mode.
Appendix
Control commands list
RS-232 Type
USB Type
Description
CR