Boot Option Settings; Lpar Manager Shutdown; Notes For System Management; Restriction When Dual-Core Cpu Is Installed In Cb 520H A1/B1/B2/B3/B4 Model - Hitachi CB 520H A1 User Manual

Logical partitioning manager, compute blade 500 series
Hide thumbs Also See for CB 520H A1:
Table of Contents

Advertisement

Boot Option Settings

When the same device path is registered in different boot options, you may
fail to install or boot the OS. It is confirmed that this problem has occurred in
Windows Server 2008.
In this case, Delete the boot option of the other and execute boot OS/Install
of OS.
The following is an example where the same device path is registered in
different boot options.

LPAR manager Shutdown

There is no way to check when the configuration information is saved. If
the time is unknown, you need to save the configuration information
before shutting down. If you shut down or reboot LPAR manager before
saving the configuration, newly changed values will be lost. See Save
Configuration Changed on LPAR manager Screen for how to save LPAR
manager configuration.
Do not turn off LPAR manager from the management module. It might
cause serious trouble to LPAR manager. (LPAR manager might not turn
on) When turning off LPAR manager, deactivate all LPARs, then shut off.

Notes for System Management

Restriction when Dual-core CPU is installed in CB 520H A1/B1/B2/
B3/B4 model
When only one dual-core CPU is installed in the server blade CB 520H A1/B1/
B2/B3/B4 model, set "Enable" to Hyper-Threading. If Hyper-Threading is
"Disable", an unexpected system-down might occur on LPARs.
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide
Figure 10-3 Boot Device Selecting Screen
Notes
10-13