ID
01003177
"Failed to set the synchronization
method of LPAR manager system time.
Value:xxx"
01003178
"Requested to set NTP server1 to
synchronize the LPAR manager system
time. Accept:xxx Value:xxx"
0100317A "Set the NTP server1 to synchronize
LPAR manager system time. Value:xxx"
0100317B "Failed to set the NTP server1 to
synchronize LPAR manager system time.
Value:xxx"
0100317C "Requested to set NTP server2 to
synchronize LPAR manager system time.
Accept:xxx Value:xxx"
0100317E
"Set NTP server2 to synchronize LPAR
manager system time. Value:xxx"
0100317F
"Failed to set NTP server2 to
synchronize LPAR manager system time.
Value:xxx"
01003180
"Requested to import the NTP settings
of the LPAR manager. Accept:xxx
From:xxx"
01003182
"Imported the NTP settings of the LPAR
manager. From:xxx"
01003183
"Failed to import the NTP settings of
the LPAR manager. From:xxx"
01003184
"Initialized all options of the FC HBA
driver. LPARxxx Slot#:xxx Port#:xxx"
01003186
"Enabled or disabled the BootFunction
of the FC HBA driver option. LPARxxx
Slot#:xxx Port#:xxx Value:xxx"
01003188
"Set the ConnectionType of the FC HBA
driver option. LPARxxx Slot#:xxx
Port#:xxx Value:xxx"
0100318A "Enabled or disabled the
MultiplePortID of the FC HBA driver
9-78
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide
Message
Messages
Operation for which an audit log is
collected
When the LPAR manager screen is used to
request change of the time synchronization
with NTP server (TimeSync) and the request
fails
When HvmSh and so on is used to request
setting change of NTP Server1 and the
request is accepted
When the LPAR manager screen is used to
request setting change of NTP Server1 and
the request succeeds
When the LPAR manager screen is used to
request setting change of NTP Server1 and
the request fails
When HvmSh and so on is used to request
setting change of NTP Server2 and the
request is accepted
When the LPAR manager screen is used to
request setting change of NTP Server2 and
the request succeeds
When the LPAR manager screen is used to
request setting change of NTP Server2 and
the request fails
When HvmSh and so on is used to request
importing of NTP setting (Import Config) and
the request is accepted
When the LPAR manager screen is used to
request importing of NTP setting (Import
Config) and the request succeeds
When the LPAR manager screen is used to
request importing of NTP setting (Import
Config) and the request fails
When HvmSh and so on is used to request
clearing of the options of the FC HBA driver
of the logical EFI and the request
immediately succeeds
When HvmSh and so on is used to request
change of the bootfunc option of the FC HBA
driver of the logical EFI and the request
immediately succeeds
When HvmSh and so on is used to request
change of the ConnectionType option of the
FC HBA driver of the logical EFI and the
request immediately succeeds
When HvmSh and so on is used to request
change of the MultiplePortID option of the FC
HBA driver of the logical EFI and the request
immediately succeeds