Removing The Cold Mirror - Christie CP2208 Service Manual

Hide thumbs Also See for CP2208:
Table of Contents

Advertisement

When reinstalling the light sensor module, recalibrate the footLambert (fL) readings for
minimum and maximum power. See the CP2208 User Manual (020-101916-xx).

Removing the cold mirror

Warning! Failure to comply with the following could result in serious injury.
UV HAZARD! Always wear protective safety clothing and a face shield when performing service with
the safety shield removed and a lamp installed.
Wear gloves when you handle the cold mirror.
1. Turn the projector off and then disconnect it from AC power.
2. Remove the lamp. See
3. Remove the side projector skin. See
4. Remove the four cold mirror heat sink plate screws and then remove the heat sink (A).
5. Remove the top two hex screws and clips holding the cold mirror.
6. Loosen the bottom two hex screws holding the cold mirror.
CP2208 Service Manual
020-101917-01 Rev. 1 (11-2015)
Replacing the lamp
on page 40.
Removing the exhaust panel skin
Parts and Module Replacement
on page 39.