10. Replace the top lid.

Aligning the fold mirror

If a corner or edge of an image is missing, the fold mirror might be misaligned with the optical
system. To correct this issue:
1. Remove the top lid and set it aside. See
2. Display a full white test pattern:
a. On the touch panel controller (TPC), tap the Test Pattern icon (
b. Tap All Test Patterns.
c. Tap RBG-12bit-Full Screen White.
3. Insert a hex driver in the first set screw (A) and a hex driver in the first cap screw (B).
4. Equally turn the set screw (A) and cap screw (B) in opposite directions until the black corner is
removed.
CP2208 Service Manual
020-101917-01 Rev. 1 (11-2015)
Removing the top lid
Set screw (x2)
A
Cap screw (x2)
B
Adjusting the Image
on page 33.