Installing the compute node

The NetBackup 5330 requires two RU rack spaces. Veritas recommends that you
install the compute node in the space on top of the primary shelf.
The rails require one RU rack space and must be installed in the upper RU of the
two required for the compute node.
To install the compute node
1
Use the rack rail templates that are provided with the compute node.
Determine which 2 RUs to use.
Determine which rack holes to use for pins and screws.
2
Locate the RUs on the front and the rear of the rack that you plan to use.
3
At the front of the rack, install a cage nut in the center hole of the lower RU on
each side.
This hole is used later to secure the compute node to the rack.
Hardware installation procedures
Installing the compute node
47