VERITAS NetBackup 5330 Installation Manual page 53

Appliance hardware
Table of Contents

Advertisement

Connecting a NetBackup 5330 compute node to a primary shelf
Compute node FC ports
Table 3-1
Compute node FC ports
Slot 1; ports 1 and 2
Slot 4; ports 1 and 2
XX
A
B
XX
Primary shelf FC ports
Table 3-2
Primary Storage Shelf FC ports
Canister A; FC Ch1 and FC Ch2
Canister B; FC Ch1 and FC Ch2
To connect the compute node to the primary shelf
1
Connect the slot 1 FC ports on the compute node to the appropriate primary
shelf canister FC ports as follows:
Connect compute node slot 1, port 2 to primary shelf canister B, FC Ch1.
Connect compute node slot 1, port 1 to primary shelf canister A, FC Ch1.
2
Connect the slot 4 FC ports on the compute node to the appropriate primary
shelf canister FC ports as follows:
Connect compute node slot 4, port 2 to primary shelf canister B, FC Ch2.
Slot 3
Slot 2
Slot 1
2 1
Ch1 Ch2
XX
XX
Ch1 Ch2
Hardware installation procedures
Slot 6
Slot 5
Slot 4
2 1
53