Hardware installation procedures

Installing the NetBackup 5330 compute node

Installing the NetBackup 5330 compute node
The NetBackup 5330 requires two RU rack spaces. Veritas recommends that you
install the compute node in the space directly that is above the Primary Shelf.
The rails require one RU rack space and must be installed in the upper RU of the
two required for the compute node.
To install the compute node
1
Use the rack rail templates that are provided with the compute node.
Determine which 2 RUs to use.
Determine which rack holes to use for pins and screws.
2
Locate the RUs on the front and the rear of the rack that you plan to use.
3
At the front of the rack, install a cage nut in the center hole of the lower RU on
each side.
This hole is used later to secure the compute node to the rack.
4
Locate the left rail, marked with an L on the side near the front. Note the
following:
The marked side of the rail must face the side of the rack cabinet when
mounted, not the side of the compute node.