VERITAS NetBackup 5330 Hardware Service Procedure

VERITAS NetBackup 5330 Hardware Service Procedure

Replacing a fan canisterin a primary storage shelf or an expansion storage shelf
Hide thumbs Also See for NetBackup 5330:

Advertisement

Quick Links

Veritas Appliance
Hardware Service Procedure
Replacing a fan canister in a Primary Storage Shelf or an Expansion
Storage Shelf
Document Number: 135
Version: 3.2 (03/06/17)
Purpose
This document describes the process for replacing a fan canister in a Primary Storage Shelf or an
Expansion Storage Shelf.
Affected Models
NetBackup 5330 Appliance
Velocity 7330 Appliance
Electrical Safety
The static discharged by human bodies can damage static-sensitive components on the boards.
When installing and maintaining the equipment, observe appropriate electrostatic safety precautions
to prevent personnel injuries or device damage.
When operating a device in an electrostatic sensitive area, you must take electrostatic-discharge
(ESD)-preventive measures. These include wearing ESD-preventive gloves, an ESD-preventive wrist
strap, and ESD-preventive clothes to avoid personnel injury or device damage.
To prevent damage to the device, pay attention to the following during operations:
Do not touch devices with bare hands because ESD from the human body may damage the
electrostatically sensitive elements on a board.
When dealing with the server or any of the internal components, wear an ESD-preventive wrist
strap, ESD-preventive gloves, and ESD-preventive suit.
1

Advertisement

loading

Summary of Contents for VERITAS NetBackup 5330

  • Page 1 This document describes the process for replacing a fan canister in a Primary Storage Shelf or an Expansion Storage Shelf. Affected Models • NetBackup 5330 Appliance • Velocity 7330 Appliance Electrical Safety The static discharged by human bodies can damage static-sensitive components on the boards.
  • Page 2 HSP 135 Fan Canister Replacement Hardware Part Replacement Procedure Removing and replacing a fan canister Before you start to replace a fan canister in a Primary Storage Shelf or an Expansion Storage Shelf, gather the following: • Replacement fan canister •...
  • Page 3 You can use the Support > ServiceAllowed command to turn on the blue light. If you cannot turn on the light, contact Veritas Technical Support. Warning: If you perform this procedure with the power turned on, you must complete it within 15 minutes to prevent the possibility of overheating the equipment.
  • Page 4 When the Fan Power LED is on and the Fan Service Action Required LED is off, the procedure has been successfully completed. If the Fan Power LED is off and the Fan Service Action Required LED is on, contact Veritas Technical Support.

This manual is also suitable for:

Velocity 7330