Installing the Velocity 7330 compute node

The Veritas Velocity 7330 requires two RU rack spaces. Veritas recommends that
you install the compute node in the space directly above the Primary Storage Shelf.
The rails require one RU rack space and must be installed in the upper RU of the
two required for the compute node.
To install the compute node
1
Locate the two RUs on the front and the rear of the rack that you plan to use.
See
"Determining the rack location"
2
At the front of the rack, install a cage nut in the center hole of the lower RU on
each side.
This hole is used later to secure the compute node to the rack.
3
Locate the left rail, marked with an L on the side near the front. Note the
following:
The marked side of the rail must face the side of the rack cabinet when
mounted, not the side of the compute node.
The rail ends contain unique points for engagement in the rack.
The square protrusion at the top should be placed in the top hole of the
RU. The round blue protrusion at the bottom should be placed in the bottom
hole of the RU.
Installing the Velocity 7330 compute node
on page 23.
LEFT
Installation procedures
37