This is the time when the triggering event occurred. The format for this parameter is
HOD-MOH-SOM (Hour-Of-Day - Minute-Of-Hour - Second-Of-Minute). HOD ranges from
0 to 23. MOH and SOM range from 0 to 59. A null value for this parameter defaults to
the time in the message header.
<locn>, <dirn>
These parameters do not apply to LMS1000. A NULL value is inserted for them.
<monval>
This is the measured value of the monitored value associated with the alarm condition. A
NULL value is inserted if there is no measured value associated with this trouble.
Parameter grouping cannot be used with this parameter.
<thlev>
This is the value of the threshold level if the condition type parameter is a threshold
violation. A NULL value means there is no threshold level associated with the alarm
condition. Parameter grouping cannot be used with this parameter.
<tmper>
This is the accumulation time period for Performance Monitoring (PM) parameters. It
represents the length of time the alarm condition has been active. Parameter grouping
cannot be used with this parameter. The format for this parameter is VAL-UN, where
valid values for VAL (value) and UN (unit) are:
<conddescr>
This parameter is a text message which provides a detailed description of the alarm,
event, or condition. It is an ASCII string enclosed within a pair of escaped quotes (\"). It
may also be used to describe any action to be taken as a result of the condition. For this
application, values are derived from the CONDITION DESCRIPTION parameter of the
LMS1000 channel or limit configuration with which the alarm condition is associated. If
the channel or limit parameter has not been configured, a NULL will be inserted for this
parameter.
<aiddet>, <obsdbhvr>, <exptdbhvr>, <dgntype>, <tblistl>
These parameters do not apply or are not implemented in LMS1000. A NULL value is
inserted for them.
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
VAL (value)
UN (unit)
1
DAY (day)
1 to 24
HR (hour)
1 to 1440
MIN (minute)
Chapter 3. Commands
Section 5847
Issue AL, July 24, 2006
Page 3-377