Section 5847
Issue AL, July 24, 2006
VPS MCA Events: The following actions performed via LMS1000 or detected by
LMS1000 (#26 below) are recorded in the events log.
Page 2-24
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
11) System battery on discharge alarm set
12) System overcurrent alarm set
13) System operating mode (float or test/equalize) changed
14) Subsystem high voltage alarm set
15) Subsystem low voltage alarm set
16) PCU toggled on or off (TR feature)
17) Number of available PCU mounting positions changed
18) Number of PCUs installed changed
19) Number/type of loads installed changed
20) Number of LVD cards installed changed
21) Subsystem overcurrent alarm set
22) Subsystem output voltage calibration reading set
23) LVD "disconnect" set
24) LVD "reconnect" set
25) ACO activated
26) Subsystem Installed
27) Subsystem Removed
28) MCA Powered Down
1) System float voltage set
2) System test/equalize voltage set
3) System high voltage shutdown set
4) System current limit set
5) System output voltage calibration reading set
6) NAG (audible alarm cutoff reset time period ) minutes set
7) Battery charge temperature compensation module's calibration voltage set
8) System high voltage alarm #1 set
9) System high voltage alarm #2 set
10) System 50% battery on discharge alarm set
11) System battery on discharge alarm set
12) System overcurrent alarm set
13) System operating mode (float or test/equalize) changed
14) Subsystem high voltage alarm set
15) Subsystem low voltage alarm set
16) PCU toggled on or off (TR feature)
17) Number of available PCU mounting positions changed
18) Subsystem overcurrent alarm set
19) Subsystem output voltage calibration reading set
20) LVD "disconnect" set
21) LVD "reconnect" set
22) Inventory reset
23) MCA custom message set
24) PCU custom message set
25) MCA remote access password set
26) LMS1000/MCA communications link broken
27) Previously downloaded configuration uploaded to the VPS. Two events are
recorded for this action. "Vortex system uploaded" and "VPS settings uploaded".
Chapter 2. Operating LMS1000
Spec. Nos. 586505000 and 5865055000 (Model LMS1000)