Advertisement

Events

On this
Maintenance > Events
may occur in the SLC unit.
1. Click the Maintenance tab and select the Events option. The following page displays:
2. Enter the following:
Event Trigger
Host to Ping
RPM
SLC™ 8000 Advanced Console Manager User Guide
page, you can define what action you want to take for events that
Figure 13-13 Maintenance > Events
From the drop-down list, select the type of incident that triggers an event. Currently,
the options are:
Receive Trap
Temperature Over/Under Limit (for Sensorsoft devices)
Humidity Over/Under Limit (for Sensorsoft devices)
Device Port Data Drop
No Internal Modem Dial Tone
Ping Host Fails
RPM Load Over Threshold
When the trigger is set to Ping Host Fails, enter the hostname, IPv4 address or
IPv6 address of the host to ping. The host will be pinged every 2 minutes.
When the trigger is set to RPM Load over Threshold, select the RPM that will be
monitored for a current that exceeds a defined threshold. The RPM needs to
support providing a current level as part of its status information. The RPM current
will be checked every 2 minutes.