v1/v2c Communities
Read-Only
Read-Write
Trap
Version 3
Security
Auth with
Encrypt with
V3 User Read-Only
User Name
Password/Retype
Password
Passphrase/
Retype
Passphrase
V3 User Read-Write
User Name
Password/
Retype Password
Passphrase/
Retype
Passphrase
V3 User Trap
User Name
SLC™ 8000 Advanced Console Manager User Guide
A string that SNMP agent provides. The default is public.
A string that acts like a password for an SNMP manager to access the read-only data
from the SLC unit SNMP, like a password for an SNMP manager to access the read-
only data the SLC SNMP agent provides, and to modify data where permitted. The
default is private.
The trap used for outgoing generic and enterprise traps. Traps sent with the Event
trigger mechanism still use the trap community specified with the Event action. The
default is public.
Levels of security available with SNMP v. 3.
No Auth/No Encrypt: No authentication or encryption.
Auth/No Encrypt: Authentication but no encryption. (default)
Auth/Encrypt: Authentication and encryption.
For Auth/No Encryp or Auth/Encrypt, the authentication method:
MD5: Message-Digest algorithm 5 (default)
SHA: Secure Hash Algorithm
Encryption standard to use:
DES: Data Encryption Standard (default)
AES: Advanced Encryption Standard
SNMP v3 is secure and requires user-based authorization to access
Enter a user ID. The default is snmpuser. Up to 20 characters.
Password for a user with read-only authority to use to access SNMP v3. The default is
SNMPPASS. Up to 20 characters.
Passphrase associated with the password for a user with read-only authority. Up to 20
characters. If this is not specified it will default to the v3 Read-Only Password.
SNMP v3 is secure and requires user-based authorization to access
Enter a user ID for users with read-write authority. The default is snmprwuser. Up to
20 characters.
Password for the user with read-write authority to use to access SNMP v3. The default
is SNMPRWPASS. Up to 20 characters.
Passphrase associated with the password for a user with read-write authority. Up to 20
characters. If this is not specified it will default to the v3 Read-Write Password.
SNMP v3 is secure and requires user-based authorization to access SLC unit MIB
objects. Enter a user ID for users with authority to send traps. The default is
snmptrapuser. Up to 20 characters.
7: Services
SLC
MIB objects.
SLC
MIB objects.
96
Need help?
Do you have a question about the SLC 8000 and is the answer not in the manual?