5. VIDEO PLOTTER OPERATION
5.4.2

How to set the plotting interval

1. Open the menu.
2. Select [2 MARKS].
3. Select [7 TRACKS].
4. Select [2 OWN TRACK] or [3 TARGET TRACK] as appropriate.
Note: For IMO-types, [3 TARGET TRACK] is not shown.
5. Select [3 SAVE INTERVAL].
6. Select the appropriate setting, then left-click.
The following tables show the relation between plotting interval settings and max-
imum track recording time. Note that the maximum recording time is different for
own tracks and target tracks.
Interval
10 s
30 s
1 min
2 min
10 s
30 s
1 min
2 min
3 min
6 min
15 min
DRAW ONLY
7. Close the menu.
5.4.3

How to set the track color (A/B-types only)

1. Open the menu.
2. Select [2 MARKS].
3. Select [7 TRACKS].
4. Select [2 OWN TRACK] or [3 TARGET TRACK] as appropriate.
5. Select [4 OWN TRACK COLOR]. The following colors are available.
• [RED] (Red)
• [GRN] (Green)
• [BLU] (Blue)
• [YEL] (Yellow)
6. Select the appropriate setting, then left-click.
7. Close the menu.
5-10
Own track recording times
Max. Recording Time
56 hours
167 hours
333 hours
667 hours
Target track recording times
Max. Recording Time
Interval
42 hours
125 hours
250 hours
500 hours
750 hours
1500 hours
3750 hours
No track data recorded.
• [CYA] (Cyan)
• [MAG] (Magenta)
• [WHT] (White)
Interval
3 min
6 min
15 min
DRAW ONLY
(One target only)
Max. Recording Time
1000 hours
2000 hours
5000 hours
No track data recorded.
Max. Recording Time
(15 targets)
3 hours
8.5 hours
16.5 hours
33.5 hours
50 hours
100 hours
250 hours
No track data recorded.