Furuno FAR-2218-BB Operator's Manual page 256

Hide thumbs Also See for FAR-2218-BB:
Table of Contents

Advertisement

FURUNO
FAR-2238S-NXT/2338S-NXT 100-230 VAC: 3.0-1.5 (5.8-2.6) A, 1 phase, 50-60 Hz
6.2
Monitor unit
MU-190
MU-231
MU-270W
6.3
HUB (option)
6.4
Transformer (RU-1803, option)
6.5
De-icer (option)
7
ENVIRONMENTAL CONDITIONS
7.1
Ambient temperature
Antenna unit
Indoor units
7.2
Relative humidity
7.3
Degree of protection
Antenna unit
Processor/ monitor unit IP22
Transceiver/ control unit IP20
HUB
7.4
Vibration
8
UNIT COLOR
8.1
Antenna unit
8.2
Processor/ transceiver unit
8.3
Control/ monitor unit
8.4
HUB
8.5
Radar console
9
PERFORMANCE MONITOR
9.1
PM-32 (X-band)
Frequency range
Input power
Output power
Step level
9.2
PM-52A (S-band, MAG)
Frequency range
Input power
Output power
Step level
9.3
PM-52B (S-band, SSD)
Frequency range
Input power
Output power
Step level
( ): 42 rpm
100-230 VAC: 0.7-0.4 A, 1 phase, 50-60 Hz
100-230 VAC: 1.0-0.6 A, 1 phase, 50-60 Hz
100-230 VAC: 0.7-0.4 A, 1 phase, 50-60 Hz
100-230 VAC: 0.1 A max. 1 phase, 50/60 Hz
440 VAC, 1 phase, 50/60 Hz
100-115/220-230 VAC: 2.6/1.3 A, 1 phase, 50-60 Hz
-25°C to +55°C (storage: -25°C to +70°C)
-15°C to +55°C (storage: -20°C to +70°C)
95% or less at +40°C
IP56
IP20 (HUB-100), IP22 (HUB-3000)
IEC 60945 Ed.4
N9.5
N2.5
N2.5
N3.0 (HUB-100), N2.5 (HUB-3000)
2.5GY5/1.5 (standard), 7.5BG7/2, 2.5G7/2, N7.5
9380 to 9440 MHz
+18 dBm to +30 dBm
st
-21 dBm (1
pulse max. output), -41 dBm (1
st
8 to 12 dB (1
pulse to last pulse)
3040 to 3080 MHz
+25 dBm to +40 dBm
st
-38 dBm (1
pulse max. output), -58 dBm (1
st
8 to 12 dB (1
pulse to last pulse)
3063.75 ±2 MHz
+5 dBm to +25 dBm
st
-52 dBm (1
pulse max. output), -72 dBm (1
st
8 to 12 dB (1
pulse to last pulse)
SP - 4
FAR-2xx8 SERIES
st
pulse min. output)
st
pulse min. output)
st
pulse min. output)
E3652S01E-M

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents