5.8.2

How to set the plotting interval

1. Open the menu.
2. Select [2 MARKS].
For A/B/W-types with Radar Plotter functionality, select [2 MARKS•CHART].
3. Select [7 TRACKS].
4. Select [2 OWN TRACK] or [3 TARGET TRACK] as appropriate.
Note: For IMO/R-types, [3 TARGET TRACK] is not shown.
5. Select [3 SAVE INTERVAL].
6. Select the appropriate setting, then left-click.
The following tables show the relation between plotting interval settings and max-
imum track recording time. Note that the maximum recording time is different for
own tracks and target tracks.
Interval
10 s
30 s
1 min
2 min
10 s
30 s
1 min
2 min
3 min
6 min
15 min
DRAW ONLY
Note: To hide own ship or target past tracks, set the interval to [OFF]. To hide both
tracks, set the interval for both own ship and targets tracks to [OFF]. Tracks plot-
ted after the setting is set to [OFF] are hidden. Previously plotted tracks remain
on-screen.
7. Close the menu.
Own track recording times
Max. Recording Time
56 hours
167 hours
333 hours
667 hours
Target track recording times
Max. Recording Time
Interval
(One target only)
42 hours
125 hours
250 hours
500 hours
750 hours
1500 hours
3750 hours
No track data recorded.
5. VIDEO PLOTTER OPERATION
Interval
Max. Recording Time
3 min
1000 hours
6 min
2000 hours
15 min
5000 hours
DRAW ONLY
No track data recorded.
Max. Recording Time
3 hours
8.5 hours
16.5 hours
33.5 hours
50 hours
100 hours
250 hours
No track data recorded.