Furuno FAR-2218-BB Operator's Manual page 213

Hide thumbs Also See for FAR-2218-BB:
Table of Contents

Advertisement

Tested item
[MAIN]
[2.5V]
[1.8V]
[1.25V]
[1.2V]
[TEMP]
[FAN1]
[FAN2]
[FAN3]
[TB]
[12V]
[3.3V]
[PWR]
[P12V]
[P48V]
[P48 V CURRENT] 0 to 3 A
[MTR1]
[MTR2]
[TX HV]
RP
3.3V, TEMP, FAN
SPU (Antenna)
[PROGRAM No.]
[ROM]
[RAM]
[DIP SWITCH]
[BOARD REV]
[IP ADDRESS]
[SPU]
[TX TYPE]
[12V]
[5V]
[3.3V]
[2.5V]
[1.8V]
[1.25V]
[1.2V_1]
[1.2V_2]
[3.3V_A]
[-10V]
[TX HV]
[MAG HEATER
VOL]
[MAG HEATER
CUR]
[IF 5V]
[IF -10V]
[MD 12V]
Magnetron Radar
2.3 to 2.7 V
1.6 to 2.0 V
1.13 to 1.38 V
1.0 to 1.3 V
-15 to +70°C
3700 to 5700 rpm
3700 to 5700 rpm
• X/S-Band radars with 24 rpm config: Not shown
• S-Band radars with 42 rpm (HSC) config: 3700 to 5700 rpm
10.8 to 13.2 V
3.0 to 3.6 V
10.8 to 13.2 V
46 to 50 V
45.1 to 51.3 V
• X/S-Band radars with 24 rpm config: Not shown
• S-Band radars with 42 rpm (HSC) config: 45.1 to 51.3 V
500 to 570 V
(Not currently used)
Shows the program version number.
OK
OK
Shows the DIP SWITCH settings.
Shows the revision number for each PCB.
Shows the IP address for the Processor Unit.
X-12kW/X-25kW/S-30kW
11.4 to 12.6 V
4.75 to 5.25 V
3.18 to 3.42 V
2.4 to 2.6 V
1.71 to 1.89 V
1.19 to 1.31 V
1.14 to 1.26 V
1.14 to 1.26 V
3.18 to 3.42 V
-10.5 to -9.5 V
500 to 560 V
• X-Band, 12 kW:
8.1 to 8.6 V or 6.8 to 7.3 V
• X-Band, 24 kW:
7.0 to 7.5 V or 5.7 to 6.2 V
• S-Band:
7.4 to 7.9 V or 6.3 to 6.8 V
• X-Band: 0.5 to 0.6 A
• S-Band: 1.1 to 1.4 A
4.75 to 5.25 V
-10.5 to -9.5 V
11.4 to 12.6 V
6. MAINTENANCE, TROUBLESHOOTING
Normal value
Solid State Radar
S-Solid
"not connect"
"not connect"
"not connect"
"not connect"
"not connect"
"not connect"
"not connect"
6-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents