Toshiba e-STUDIO520 Service Handbook page 165

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

Classifi-
Code
cation
1479
User
Default setting of sharp-
interface
ness
1481
General
User data management
clearing
1482
General
User data department
management
1483
General
User data recovery
1484
Network
Authentication method of
"Scan to Email"
1485
Network
Setting whether use of
Internet FAX is permitted
or not when it is given an
authentication
1487
Network
"From" address assign-
ment method when it is
given an authentication
1489
Network
Setting for "From" address
edit at "Scan to Email"
1491
Network
E-mail domain name
1492
Paper
Detection method of 13"
feeding
LG for single-size docu-
ment
1493
Network
Role Base Access Func-
tion
1494
General
Limitation check method
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Default
Func-
<Accept-
Items
tion
value>
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
2 - 139
06/09
RAM
Contents
able
5
SYS
1: -4
2: -3
<1-9>
3: -2
4: -1
5: 0
6: +1
7: +2
8: +3
-
-
All the user data in the
database and backup
files can be deleted.
0
SYS
0: Invalid
<0-1>
1: Valid
*
When this code is
set to "1" (Valid), the
department man-
agement setting
(08-629) should be
"1" (Valid).
-
-
The data in the data-
base is overwritten with
the data in the backup
file.
0
SYS
0: Disable
<0-2>
1: SMTP authentication
2: LDAP authentication
0
SYS
0: Not permitted
<0-1>
1: Permitted
0
SYS
0: "User name" + @ +
<0-2>
"Domain name"
1: LDAP search
2: Use the address
registered in "From"
field of E-mail set-
ting
0
SYS
0: Not permitted
<0-1>
1: Permitted
SYS
96+2 (delimiter) charac-
ter
ASCII sequence only
0
SYS
0: Disabled
<0-1>
1: Enabled
0
SYS
0: Function off (No
<0-1>
restriction on data
saving and other
operations)
1: Function on (Data
saving and other
operations have
some restrictions)
0
SYS
0: Checked at every
<0-1>
page printed
1: Checked at every
job printed
e-STUDIO520/523/600/603/720/723/850/853
ERROR CODE AND SELF-DIAGNOSTIC MODE
Proce-
dure
1
9: +4
3
1
3
1
1
1
1
11
1
1
2
2

Hide quick links:

Advertisement

Table of Contents
loading