Toshiba e-STUDIO520 Service Handbook page 132

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

Classifi-
Code
cation
486
Laser
Timing of auto-clearing of
polygonal motor pre-run-
ning rotation
488
Laser
Setting of polygonal motor
type
489
Laser
Polygonal motor rotational
speed at ready status
502
Image
Error diffusion and dither
setting at photo mode
503
User
Default setting of density
interface
adjustment
e-STUDIO520/523/600/603/720/723/850/853
ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08)
Func-
Items
tion
ALL
ALL
ALL
PPC
PPC
2 - 106
07/11
Default
<Accept-
RAM
able
value>
0
SYS
This setting to switch
<0-2>
the polygonal motor to
the standby rotation
when a certain period of
time has passed from
the pre-running. In this
code, the period of time
to switch the motor sta-
tus to the standby rota-
tion is set.
0: 15 sec. 1: 30 sec.
2: 45 sec.
*
This setting is
enabled when "0" or
"2" is set in 08-483
and also "0" is set in
08-484. The rota-
tional status in the
ready status can be
set in 08-485
2
M
The type of the polygo-
<2-3>
nal motor is set.
2: 2-clock type
3: 3-clock type
*
This setting is
enabled only for e-
STUDIO850.
Refer to
M
<e-STUDIO520/523/
contents
600/603/720/723>
<0-5>
0: 60,236.22 rpm
1: 44,500 rpm
2: 40,000 rpm
3: 35,000 rpm
4: Unused
5: Unused
<e-STUDIO850/853>
0: 36,318.898 rpm
1: Unused
2: Unused
3: Unused
4: Unused
5: Unused
<Default value>
e-STUDIO520/523: 1
e-STUDIO600/603: 1
e-STUDIO720/723: 1
e-STUDIO850/853: 0
1
SYS
Sets the image repro-
<0-1>
duction method at
photo mode.
0: Error diffusion
1: Dither
0
SYS
0: Automatic
<0-1>
1: Manual (Center)
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved