22)Blotched image
Defective area
Paper
Transfer belt unit
High-voltage transformer
(Transfer charger)
e-STUDIO520/523/600/603/720/723/850/853
TROUBLESHOOTING
Fig. 5-22
Step
Check items
1
Is the paper type corresponding to its
mode?
2
Is the paper too dry?
3
Is the surface of the transfer belt sup-
ply roller dirty with toner?
4
Does the transfer belt exceed its nor-
mal life span?
5
Is the output from the high-voltage
transformer normal?
5 - 152
Prescription
Check the paper type and mode.
Change the paper.
Clean it with alcohol.
Replace the transfer belt.
Adjust the output. Replace the trans-
former if necessary.