3.

ADJUSTMENT

When the power should be turned OFF, be sure to shut down the equipment by pressing the [ENERGY
SAVER] button for a few seconds.
3.1
Adjustment of Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
Note:
Note:
Check if the cleaning blade is pressed against the drum before performing this adjustment.
<Procedure> (Adjustment Mode (05-200))
(1)
Install the into the equipment.
(2)
While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
[ POWER ]
(3)
Key in code [200] and press the [START] button.
The display changes as follows.
[ 200 ]
Notes:
A indicates the controlled value of the auto-toner sensor output.
B indicates the output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
C indicates the latest adjustment value.