Toshiba e-STUDIO520 Service Handbook page 513

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

21)Uneven light distribution
Defective area
Original glass
Main charger
Discharge LED
Scanner
Exposure lamp
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Fig. 5-21
Step
Check items
1
Is the original glass dirty?
2
Are the needle electrode, main
charger grid and main charger case
dirty?
3
Is the discharge LED dirty?
4
Is any of the discharge LEDs off?
5
Are the reflector, exposure lamp, mir-
rors, lens, and original glass (espe-
cially the position of shading
correction plate) dirty?
6
Is the exposure lamp discolored or
degraded?
5 - 151
06/09
Prescription
Clean the original glass.
Clean or replace them.
Clean the discharge LED.
Replace the discharge LED.
Clean them.
Replace the exposure lamp.
e-STUDIO520/523/600/603/720/723/850/853