Toshiba e-STUDIO520 Service Handbook page 396

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

[E450] Option LCF side cover opened jam
Is the LCF front cover open?
YES
NO
Is the LCF side cover opening/closing switch working?
(Perform the input check in the test mode: 03-[FAX]OFF/[5]/[B])
l
NO
l
l
l
l
l
l
l
l
l
l
l
l
YES
1) Replace the LCF board.
2) Replace the LGC board.
[E460] Right center cover (bypass feed unit cover) open jam
Is the bypass feed unit cover open?
YES
NO
Is the bypass feed unit cover sensor working?
(Perform the input check in the test mode: 03-[ENERGY SAVER]OFF/[6]/[H])
l
NO
l
l
l
l
l
l
l
YES
Replace the LGC board.
e-STUDIO520/523/600/603/720/723/850/853
TROUBLESHOOTING
Remove the paper if there is any, then close the cover.
1) Check if the connector of the LCF side cover opening/closing switch
is disconnected.
2) Check if either of the connectors CN100 or CN106 on the LCF board
is disconnected.
3) Check if the connector CN338 on the LGC board is disconnected.
4) Check if the connector pins are disconnected and the harnesses are
open circuited.
5) Check if the conductor patterns on the LCF board and LGC board are
short circuited or open circuited.
6) Replace the LCF side cover opening/closing switch.
7) Replace the LCF board.
8) Replace the LGC board.
Remove the paper if there is any, then close the bypass feed unit cover.
1) Check if the connector of the bypass feed unit cover sensor is dis-
connected.
2) Check if the connector CN338 on the LGC board is disconnected.
3) Check if the connector pins are disconnected and the harnesses are
open-circuited.
4) Check if the conductor patterns on the LGC board are short- or open-
circuited.
5) Replace the bypass feed unit cover sensor.
6) Replace the LGC board.
5 - 34
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents