[2C67] NIC time-out error
[2C68] NIC access error
[2C6D] System error
Turn the power OFF and then back ON. Perform the job in error again.
If the error still occurs, replace the SYS board.
[2C69] SMTP server connection error
Reset the login name and password of SMTP server and perform the job again.
Check if the SMTP server is operating properly.
[2C6A] HOST NAME error (No RFC error)
Check if there is an illegal character in the device name.
Delete the illegal character and reset the appropriate device name.
[2C6B] Terminal mail address error
Check if the SMTP authentication method is correct.
Check if there are any illegal characters in the Terminal mail address.
Select the correct SMTP authentication method. Delete the illegal characters and reset the mail
address. Then try again.
[2C6C] Destination mail address error (No RFC error)
Check if there is an illegal character in the Destination mail address.
Delete the illegal character and reset the appropriate Destination mail address, then perform the job
again.
[2C70] SMTP client OFF
Set the SMTP valid and perform the job again.
[2C71] SMTP authentication ERROR
Check that SMTP authentication method, login name and password are correct, then perform authenti-
cation again.
[2C72] POP Before SMTP ERROR
Check that both the POP Before SMTP setting and POP3 setting are correct, then perform authentica-
tion again.
[2C80] E-mail transmission failure when processing E-mail job received
Reset the "Received InternetFax Forward".
e-STUDIO520/523/600/603/720/723/850/853