<Procedure>
(1)
While pressing [0] and [5] simultaneously,
turn the power ON.
(2)
Press [FAX] to make a copy of any image on
a sheet of A3/LD paper.
(3)
Key in [308] and press the [START] button to
move the carriage to the adjustment position.
(4)
Remove the original glass.
(5)
Make an adjustment in the order of step 1
and 2.
Step 1
-
In case of A:
Tighten the mirror-3 adjustment screw
(CW).
-
In case of B:
Loosen the mirror-3 adjustment screw
(CCW).
Step 2
-
In case of C:
Tighten the mirror-1 adjustment screw
(CW).
-
In case of D:
Loosen the mirror-1 adjustment screw
(CCW).