Check Of Sensor Operations 2 - Toshiba e-STUDIO520 Service Handbook

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

3.15.4

Check of sensor operations 2

This is a mode 2 to check each sensor operation separately.
(1)
Turn ON the power with pressing the control panel mode key and start key. (The start LED blinks
in green.)
(2)
Press the mode key and set up the mode LED1, 2 to blink and mode LED3, 4 to light OFF, and
press the start key. (The start LED lights ON in green.)
* With pressing the mode key for more than 1 sec., all the mode LED light OFF and become
able to be reset.
(3)
Check the ON/OFF status of each sensor through the mode LED display.
* The display is switched whenever the start key is pressed.
LED display
When the start switch is OFF:
Mode LED
LED1
LED2
LED3
LED4
When the start switch is ON:
Mode LED
LED1
LED2
LED3
LED4
e-STUDIO520/523/600/603/720/723/850/853
ADJUSTMENT
Display
Light OFF
Joint sensor OFF
Light ON
Joint sensor ON
Light OFF
Tray open/close sensor OFF
Light ON
Tray open/close sensor ON
Light OFF
Transport cover 1 open/close
sensor OFF
Light ON
Transport cover 1 open/close
sensor ON
Light OFF
Transport cover 2 open/close
sensor OFF
Light ON
Transport cover 2 open/close
sensor ON
Display
Light OFF
Dip-switch 1 OFF
Light ON
Dip-switch 1 ON
Light OFF
Dip-switch 2 OFF
Light ON
Dip-switch 2 ON
Light OFF
Dip-switch 3 OFF
Light ON
Dip-switch 3 ON
Light OFF
Dip-switch 4 OFF
Light ON
Dip-switch 4 ON
Sensor status
Sensor status
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
3 - 86