<Updating FAX ROM>
Important:
Before updating the FAX ROM, make sure to print out the current Function list for mainte-
nance, Function list (ADMIN), Phone book number information and Group number informa-
tion. In case the updating is failed and the registered information of the users is lost for some
reason, re-register the user information referring to the lists and recover it.
Confirm the following items before turning OFF the power of the equipment. Turning OFF the
power may clear the data below.
-
Confirm that the "MEMORY RX" LED is OFF and there are no memory reception data.
-
Print the "Mailbox/Relay box report" and then confirm that there are no F code data.
-
Press the [JOB STATUS] button to display the screen and then confirm that there are no
memory transmission data.
(1)
Install the ROM to the download jig.
Make sure the direction is correct (
(2)
Shut down the equipment.
(3)
Remove the cover plate.
(4)
Connect the download jig with the jig connector (CN602) on the FAX board.
(5)
Turn ON the power while [0] button and [8] button are pressed simultaneously. Updating starts
automatically and the LED on the download jig lights.
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
P.6-4 "Fig. 6-2 Jig board: K-PWA-DLM-320").
Cover plate
Fig. 6-35
Connector
Fig. 6-36
6 - 37
05/05
e-STUDIO520/523/600/603/720/723/850/853
FIRMWARE UPDATING