(2)
Step 2
Case C:
Loosen 2 fixing screws and then turn the adjustment screw counterclockwise.
Case D:
Loosen 2 fixing screws and then turn the adjustment screw clockwise.
Note:
Note:
When adjusting, refer to the hinge position (scribed line) and be sure not to move it from the
hinge position ±0.5 mm or further. Otherwise, image failures such as a jitter may occur.
e-STUDIO520/523/600/603/720/723/850/853
ADJUSTMENT
C
Paper
Original
Fig. 3-68
Fig. 3-69
© 2005 - 2007 TOSHIBA TEC CORPORATION All rights reserved
3 - 62
D
Adjustment screw