7.3.2
Applicable Tools
The following table lists the tools that you can use to perform jogging and the applicable tool
functions.
Tool
Digital Operator
SigmaWin+
7.3.3
Operating Procedure
Use the following procedure to jog the motor.
1.
Select Test Run - Jog from the menu bar of the Main Window of the SigmaWin+.
The Jog Operation Dialog Box will be displayed.
2.
Read the warnings and then click the OK Button.
3.
Check the jogging speed and then click the Servo ON Button.
The display in the Operation Area will change to Servo ON.
Information
Function
Fn002
Test Run - Jog
To change the speed, click the Edit Button and enter the new speed.
7.3 Trial Operation for the Servomotor without a Load
Operating Procedure Reference
Σ-7-Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
Operating Procedure on page 7-7
7.3.2 Applicable Tools
7-7