15.1 List of Parameters
15.1.2 List of Parameters
Parameter
No.
Pn507
Pn508
Pn509
Pn50A
Pn50B
Pn50E
Pn50F
Pn510
Pn511
Pn512
Pn514
Pn516
Pn517
Pn518
Pn51B
Pn51E
Pn520
Pn522
Pn524
Pn526
Pn528
Pn529
Pn52A
Pn52B
Pn52C
Pn52D
15-20
Name
Brake Reference Out-
2
put Speed Level
Servo OFF-Brake Com-
2
mand Waiting Time
Momentary Power Inter-
2
ruption Hold Time
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Reserved parameter
2
(Do not change.)
Safety Module-Related
−
Parameters
Motor-Load Position
4
Deviation Overflow
Detection Level
Position Deviation Over-
2
flow Warning Level
Position Deviation Over-
4
flow Alarm Level
Positioning Completed
4
Width
4
Near Signal Width
Position Deviation Over-
4
flow Alarm Level at
Servo ON
Position Deviation Over-
2
flow Warning Level at
Servo ON
Speed Limit Level at
2
Servo ON
Multiplier per Fully-
2
closed Rotation
2
Overload Warning Level
Base Current Derating
2
at Motor Overload
Detection
Reserved parameter
2
(Do not change.)
Setting
Setting
Default
Range
Unit
Setting
-1
0 to 10,000
100
1 min
10 to 100
10 ms
50
20 to 50,000
1 ms
20
1881
−
−
hex
8882
−
−
hex
0000
−
−
hex
0100
−
−
hex
0000
−
−
hex
6543
−
−
hex
0000
−
−
hex
0000
−
−
hex
8888
−
−
hex
0000
−
−
hex
−
−
−
1 refer-
0 to
ence
1000
1,073,741,824
unit
10 to 100
1%
100
1 refer-
1 to
524288
ence
1,073,741,823
0
unit
1 refer-
0 to
ence
7
1,073,741,824
unit
1 refer-
1 to
107374
ence
1,073,741,824
1824
unit
1 refer-
1 to
524288
ence
1,073,741,823
0
unit
10 to 100
1%
100
-1
0 to 10,000
10000
1 min
0 to 100
1%
20
1 to 100
1%
20
10 to 100
1%
100
−
−
50
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
Rotary
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
−
−
All
−
−
All
−
−
All
−
−
All
−
−
All
−
−
All
−
−
All
−
−
All
−
−
All
−
−
All
−
−
All
Immedi-
Rotary
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
Rotary
Setup
ately
Immedi-
Rotary
Tuning
ately
Immedi-
All
Setup
ately
After
All
Setup
restart
−
−
All
Continued on next page.
Refer-
ence
page
5-31
page
5-31
page
6-5
−
−
−
−
−
−
−
−
−
−
−
page
10-8
page
14-47
page
8-7,
page
14-5
page
8-66
page
8-66
page
8-7
page
8-7
page
8-7
page
10-8
page
5-39
page
5-39
−