YASKAWA SGD7S Product Manual page 455

E-7-series ac servo drive, e-7s servopack, command option attachable type with devicenet module
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Alarm Number:
Possible Cause
Alarm Name
The order of phases
U, V, and W in the
motor wiring is not
correct.
There is an error in the
setting of Pn080 =
n.X (Motor
Phase Selection).
A.C10:
Servomotor Out
of Control
(Detected when
A failure occurred in
the servo is
the encoder.
turned ON.)
A failure occurred in
the SERVOPACK.
The linear encoder
signal level is too low.
The count-up direc-
tion of the linear
A.C20:
encoder does not
Phase Detection
match the forward
Error
direction of the Mov-
ing Coil in the motor.
The polarity sensor
signal is being
affected by noise.
The polarity sensor is
protruding from the
Magnetic Way of the
motor.
The setting of Pn282
A.C21:
(Linear Encoder Pitch)
Polarity Sensor
is not correct.
Error
The polarity sensor is
not wired correctly.
The polarity sensor
failed.
The SERVOPACK
A.C22:
phase information is
Phase Informa-
different from the lin-
tion Disagree-
ear encoder phase
ment
information.
Confirmation
Check the Servomotor
Make sure that the Servo-
wiring.
motor is correctly wired.
Check the setting of
Set Pn080 = n.X to
Pn080 = n.X.
an appropriate value.
If the motor wiring is cor-
rect and an alarm still
occurs after turning the
power supply OFF and
ON again, the Servomotor
or linear encoder may be
faulty. Replace the Servo-
motor or linear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Fine-tune the mounting of
Check the voltage of
the scale head. Or,
the linear encoder sig-
replace the linear
nal.
encoder.
Check the setting of
Pn080 = n.X
Change the setting of
(Motor Phase Selec-
Pn080 = n.X.
tion). Check the installa-
Correctly reinstall the lin-
tion orientation for the
ear encoder or Moving
linear encoder and
Coil.
Moving Coil.
Correct the FG wiring.
Implement countermea-
sures against noise for the
polarity sensor wiring.
Correctly reinstall the
Check the polarity sen-
Moving Coil or Magnetic
sor.
Way of the motor.
Check the setting of
Check the specifications
Pn282 (Linear Encoder
of the linear encoder and
Pitch).
set a correct value.
Check the wiring of the
Correct the wiring of the
polarity sensor.
polarity sensor.
Replace the polarity sen-
sor.
Perform polarity detec-
tion.
14.2 Alarm Displays
14.2.2 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
page 5-23
page 5-23
page 5-18
page 5-28
Continued on next page.
14
14-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents

Save PDF